{"id":3771,"date":"2026-11-22T03:14:45","date_gmt":"2026-11-21T19:14:45","guid":{"rendered":"http:\/\/www.interalumina.com\/blog\/?p=3771"},"modified":"2026-11-22T03:14:45","modified_gmt":"2026-11-21T19:14:45","slug":"do-i-need-bracing-for-purlins-and-girts-416d-5d681b","status":"publish","type":"post","link":"http:\/\/www.interalumina.com\/blog\/2026\/11\/22\/do-i-need-bracing-for-purlins-and-girts-416d-5d681b\/","title":{"rendered":"Do I need bracing for purlins and girts?"},"content":{"rendered":"<p>Hey there, I\u2019m Jake, and for the better part of a decade, I\u2019ve spent my days working side by side with contractors, steel fabricators, and building owners across the country as a purlins and girts supplier. The question I get asked more than any other\u2014usually right after someone asks, \u201cWhat even <em>are<\/em> purlins and girts?\u201d\u2014is this: \u201cDo I need bracing for my purlins and girts?\u201d It\u2019s not a yes\/no answer, and that\u2019s the part that trips people up. I\u2019ve seen guys cut corners on bracing to save a few bucks, only to get a call at 2 a.m. because a girt bent during a heavy rain or a gust of wind took out part of a warehouse wall. Today, I want to break this down like I do for my customers at the job site, no fancy jargon, just real-world stuff you can actually use. <a href=\"https:\/\/www.gneesteelstructure.com\/structural-steel-components\/purlins-girts\/\">Purlins &#038; Girts<\/a><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.gneesteelstructure.com\/uploads\/41694\/small\/steel-sheet-piles-u-z-omega-types-fora9263.png\"><\/p>\n<p>First, let\u2019s make sure we\u2019re on the same page about what we\u2019re talking about, because I\u2019ve seen more miscommunication here than anywhere else in this business. Purlins are those steel beams that run horizontally (well, almost horizontally) along the roof of a metal building, right? They sit on top of the rafters, and they\u2019re what the roof panels attach to. Girts are basically the wall version of purlins\u2014they run horizontally along the building\u2019s side walls, and they\u2019re what the wall panels bolt to. Both are usually made of galvanized steel, which is standard for durability, but their job is to hold up the cladding, which in turn holds back the wind, snow, and even the occasional heavy object like a falling tree branch.<\/p>\n<p>Now, what\u2019s bracing? Think of it as the backbone for your purlins and girts, the piece that keeps them from twisting or moving sideways when they have to hold weight. A lot of people see a purlin sitting on a rafter and a girt bolted to a column, and they think, \u201cThat\u2019s solid enough.\u201d But steel beams (especially thin-wall, which is what most of us use for light commercial and agricultural buildings) have a weak axis. If you apply force sideways\u2014like wind pushing on a wall panel, or snow loading the edge of a roof panel that pulls a purlin sideways\u2014without something to stop that movement, the beam will twist, bend, or even buckle. Bracing is the material we add to counter that weak-axis force. It can be diagonal steel rods, flat bars, steel angles, even sometimes the roof or wall panels themselves, though that\u2019s only part of the story.<\/p>\n<p>So, do you need it? The short answer is: It depends on three big factors. Let\u2019s go through each one, because skipping any of these is where mistakes happen.<\/p>\n<p>First factor: Building location and environmental loads. This is the most important one, and it\u2019s non-negotiable. If you\u2019re building in a place that gets heavy wind\u2014like a coastal area, or somewhere that\u2019s prone to thunderstorms with 80+ mph gusts\u2014bracing isn\u2019t just a good idea, it\u2019s required by code. I had a customer in Tampa a couple years back who tried to skip girt bracing on a small warehouse he was building for his boat repair business. He said, \u201cI saved $1,200 by not buying those diagonal rods, and I used that to buy a nicer break room fridge.\u201d Then a Category 2 hurricane hit a month after he finished. The wind pushed the east wall out about 18 inches, and half his wall panels were torn off. The insurance adjuster said the lack of bracing was the main cause, and he ended up paying $18,000 in repairs, plus he had to shut down his business for two weeks. That\u2019s a story I tell every time a customer suggests cutting bracing.<\/p>\n<p>Wind isn\u2019t the only environmental load. Snow is a big one too, especially for roof purlins. If you\u2019re building in a mountain town, or even just a northern state that gets 3+ feet of wet snow in the winter, the weight of that snow can put a lot of sideways force on the purlins. Wet snow is heavy\u2014like 20 pounds per square foot, more than three times the weight of dry, powdery snow. I once helped a guy in Minnesota who built a hay storage barn without purlin bracing. The roof held up the first winter, but when the second winter hit and we got that record snowfall in 2021, the edge of the roof caved in. The purlins twisted because they had no bracing to hold them against the snow\u2019s side load. The repair cost was way more than the bracing would have been, and he lost a whole season of hay storage.<\/p>\n<p>Other environmental factors: Seismic activity. If you\u2019re building in an area with frequent earthquakes\u2014like California, the Pacific Northwest, or parts of the Southeast\u2014code requires additional bracing for both purlins and girts to handle the side-to-side movement of the ground. Even for agricultural buildings in low-seismic areas, I always recommend at least minimal bracing, because tractors and farm equipment can accidentally hit walls, and that sudden impact can bend an unbraced girt.<\/p>\n<p>Second factor: The type and size of your purlins and girts. Not all steel beams are created equal. When we supply purlins and girts, we use different gauges (thicknesses) and shapes. For example, we sell both C-channel and Z-shaped purlins\u2014Z-purlins are more common because they overlap at the rafters, which creates a stronger connection, but both have a weak axis. The thinner the gauge (like 14-gauge vs. 12-gauge), the more flex they have, so the more they need bracing. If you\u2019re using a 12-gauge purlin for a small residential garage, that\u2019s one thing, but if you\u2019re using a 14-gauge purlin for a 100-foot-wide warehouse, that\u2019s a different story.<\/p>\n<p>Span length is huge too. Span is the distance between supports\u2014for a purlin, that\u2019s the distance between two rafters; for a girt, that\u2019s the distance between two columns. The longer the span, the more the beam can twist under load. I have a general rule I tell customers: If a purlin spans more than 20 feet, or a girt spans more than 15 feet, you need bracing. But that\u2019s a rough estimate\u2014for heavier loads or more extreme environments, that number drops. Last year, we supplied purlins for a 120-foot-wide retail building in Oklahoma, where wind speeds regularly hit 100 mph. Even though the purlins were 12-gauge with a 25-foot span, we had to add extra bracing at every third rafter, not just at the ends. The architect on that project said that was required by the local building code, and I agreed\u2014there was no way those purlins would handle the wind without it.<\/p>\n<p>Third factor: The type of building and its use. This is something a lot of people overlook. A small residential garage that\u2019s only going to hold a car and a lawnmower is way different from a large warehouse that\u2019s going to store heavy equipment, or a gym that has exposed roof trusses and might have events where people hang things from the ceiling. If your building has cranes or other overhead lifting equipment, that\u2019s even more load you have to account for. The crane\u2019s movement can create side loads on the roof purlins, so you need extra bracing there too.<\/p>\n<p>I also work with a lot of agricultural clients, and their needs are unique. Hay storage barns have that dry, fluffy snow load issue I mentioned earlier, but they also have equipment moving around inside that can hit the walls. Horse barns have the same wall impact risk, plus they\u2019re often in areas with high wind from open fields. I once had a customer build a horse barn in Iowa that only had bracing on the ends of the girts. A group of horses spooked, ran into the wall, and bent a girt right in the middle of the span. The horses were okay, but the wall panel tore, and he had to replace the girt and the panel. That would have been avoided if we\u2019d added intermediate bracing along the girt span.<\/p>\n<p>Now, let\u2019s talk about when you <em>might<\/em> be able to get away without bracing. It\u2019s really only for small, low-load buildings in mild environments. For example, a 20-foot-wide residential garage in a place where wind never gets above 50 mph, and snow load is less than 20 psf. Even then, I still recommend at least minimal bracing\u2014like diagonal rods at each end of the purlin run. I\u2019ve seen too many garages that got a surprise gust of wind and had their roof panels lift because the purlins twisted. Another case where you might not need full bracing is if you\u2019re using a standing-seam roof panel that\u2019s properly fastened to the purlins. The standing-seam panel acts as additional bracing, because it\u2019s connected to every purlin, so it helps prevent twisting. But even then, for spans over 20 feet, I still add some purlin bracing\u2014never skip it entirely.<\/p>\n<p>Wait, let\u2019s make sure we clear up a common myth here. A lot of people think that if the roof and wall panels are attached tightly, that\u2019s enough bracing. That\u2019s only partially true. The panels do add some rigidity, but they\u2019re thin and flexible, especially metal panels that are only 26 or 24 gauge. They can help, but they won\u2019t stop a girt from twisting during a heavy wind gust or a snow load event. I always compare it to a bookshelf: The shelves are like purlins\/girts, and the back panel is like the roof\/wall panel. The back panel helps keep the shelf square, but if you push the end of the shelf sideways, it will twist before the back panel gives much resistance. That\u2019s exactly how this works.<\/p>\n<p>Now, how much bracing do you need, and what type? For purlins, common bracing materials are diagonal steel rods (usually 3\/8-inch or 1\/2-inch diameter) or flat bars. You space them at intervals along the purlin run, usually every 10 to 15 feet, depending on span and load. For girts, it\u2019s similar\u2014diagonal rods or angles, spaced every 12 to 18 feet, with extra bracing at door openings, because doors create weak points in the wall. If you\u2019re dealing with very high wind or seismic loads, you might need diagonal bracing in both directions for girts, or even additional steel angles to tie the girts to the columns.<\/p>\n<p>The cost of bracing is negligible compared to the cost of repairing a failed beam. When I price out a project for a customer, I include bracing in the quote upfront, because I don\u2019t want them to be surprised later. Last quarter, I quoted a small warehouse for a customer in Georgia, and the total bracing cost was less than 2% of the total purlin and girt cost. That\u2019s it\u20142%\u2014for the piece that keeps their building standing when the wind picks up. The time I had the customer in Tampa, the damage cost was 15 times the total bracing cost he skipped. That\u2019s not a risk worth taking.<\/p>\n<p>I know, I know\u2014every customer wants to save money where they can, especially on a building project that already has a lot of expenses. But cutting corners on bracing is one of the worst places to do that. It\u2019s not an optional accessory, like a nicer paint color or extra insulation. It\u2019s a structural component that\u2019s required by most building codes, and it\u2019s the difference between a building that stands for 50 years and one that gets damaged in its first big storm.<\/p>\n<p>At the end of the day, the answer to \u201cDo I need bracing for purlins and girts?\u201d is this: If your building is in a high-wind, high-snow, or seismic area; if your purlins or girts have long spans, thin gauges, or support heavy loads; or if your building is for agricultural, commercial, or industrial use, then yes, you need bracing. If it\u2019s a small, low-residential building in a mild climate, you might be able to get away with minimal bracing, but you should still strongly consider it.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.gneesteelstructure.com\/uploads\/41694\/small\/customized-processing-cross-shaped-steela3232.png\"><\/p>\n<p>I\u2019ve been in this business long enough to see the mistakes, and I want to help you avoid them. I supply high-quality purlins and girts, and I can also help you calculate exactly how much bracing you need for your specific project, based on your location, building size, and intended use. I don\u2019t do one-size-fits-all, because I know every project is different. If you\u2019re planning a new building, or you\u2019re renovating an old one, don\u2019t guess about bracing. Reach out to me to discuss your needs, and we can work together to make sure your structure is safe, code-compliant, and built to last.<\/p>\n<p><a href=\"https:\/\/www.gneesteelstructure.com\/miscellaneous-steel\/\">Miscellaneous Steel<\/a> References:<\/p>\n<ol>\n<li>American Iron and Steel Institute. (2020). Cold-Formed Steel Design Manual.<\/li>\n<li>International Code Council. (2021). International Building Code, Chapter 22: Metal Building Systems.<\/li>\n<li>Steel Framing Alliance. (2019). Best Practices for Purlins and Girts Bracing.<\/li>\n<li>Federal Emergency Management Agency. (2018). Wind Mitigation for Residential and Commercial Buildings.<\/li>\n<\/ol>\n<hr>\n<p><a href=\"https:\/\/www.gneesteelstructure.com\/\">GNEE Steel Structure (Tianjin) Co., Ltd.<\/a><br \/>As one of the most professional purlins &#038; girts manufacturers and suppliers in China, we have world-leading production equipment and strong manufacturing capabilities. Please rest assured to buy customized purlins &#038; girts at competitive price from our factory. For quotation, contact us now.<br \/>Address: No.4-1114, Beichen Building, Beicang Town, Beichen District, Tianjin, China<br \/>E-mail: global@gneesteels.com<br \/>WebSite: <a href=\"https:\/\/www.gneesteelstructure.com\/\">https:\/\/www.gneesteelstructure.com\/<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Hey there, I\u2019m Jake, and for the better part of a decade, I\u2019ve spent my days &hellip; <a title=\"Do I need bracing for purlins and girts?\" class=\"hm-read-more\" href=\"http:\/\/www.interalumina.com\/blog\/2026\/11\/22\/do-i-need-bracing-for-purlins-and-girts-416d-5d681b\/\"><span class=\"screen-reader-text\">Do I need bracing for purlins and girts?<\/span>Read more<\/a><\/p>\n","protected":false},"author":963,"featured_media":3771,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[3734],"class_list":["post-3771","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-industry","tag-purlins-girts-4e34-5e1e5e"],"_links":{"self":[{"href":"http:\/\/www.interalumina.com\/blog\/wp-json\/wp\/v2\/posts\/3771","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/www.interalumina.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/www.interalumina.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"http:\/\/www.interalumina.com\/blog\/wp-json\/wp\/v2\/users\/963"}],"replies":[{"embeddable":true,"href":"http:\/\/www.interalumina.com\/blog\/wp-json\/wp\/v2\/comments?post=3771"}],"version-history":[{"count":0,"href":"http:\/\/www.interalumina.com\/blog\/wp-json\/wp\/v2\/posts\/3771\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/www.interalumina.com\/blog\/wp-json\/wp\/v2\/posts\/3771"}],"wp:attachment":[{"href":"http:\/\/www.interalumina.com\/blog\/wp-json\/wp\/v2\/media?parent=3771"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/www.interalumina.com\/blog\/wp-json\/wp\/v2\/categories?post=3771"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/www.interalumina.com\/blog\/wp-json\/wp\/v2\/tags?post=3771"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}